Medium Voltage VFD Gallery
 

 Print   
 Medium Voltage VFD

Medium Voltage VFD Motor Controller

Liquid Cooled Components
Active Front End - No Transformer
3300 - 6900 VAC
700 - 2500 HP


4160 Volt VFD Underground Motor Controller

  • Skid-Mounted Continuous Weld Design
  • Input and Output Couplers Standard
  • Rubber Tire Option
  • Voltages from 3300 to 6900 AC
  • Horsepowers from 750 to 2500
  • Regenerative Applications Standard
  • Constant Torque Duty - 150% Overload Standard
  • Custom Design Allows for 250% Overload

PowerFlex 7000 Kit
Rockwell Automation PowerFlex 7000 Liquid-Cooled Direct-to-Drive kit packaged for Underground Use

  • Active Front End (AFE) is Regenerative - Standard
  • AFE means no Integral Transformer Required
  • Direct-to-Drive (D2D) means 4160 vac In and 4160 vac Out to Motor
  • Liquid Cooled Components Stay Cooler and Cleaner = Longer Life
  • Reduces Harmonics on Electrical Systems

 Liquid Cooling for Longer Life!

  • Closed-Loop De-Ionizing Liquid Cooling
  • Integral Flat Plate Heat Exchanger Keeps Closed-Loop System Clean and Contained
  • Flange Fittings for Mine Cooling Water Input and Hot Water Return
  • Redundant Pumps for Ease of Maintenance
  • Controls Monitor Temperature, Pressure, and Conductivity of Cooling Liquid

Underground Mining Equipment VFD Motor Controls

  • Face Conveyor and Stageloader Applications
  • Torque and Speed Control
  • Enhanced Overload Capacity
  • Allows Face Conveyor to Operate at Reduced Speeds:
    • Minimizes Chain Wear by up to 40%
    • Reduces Energy Costs
    • Extends Time Between Rebuilds
  • Extreme Overload Capabilities:
    • PowerFlex 7000 Kit May be Customized
    • Normal Duty at 110%, Heavy Duty at 150%
    • Mine Duty at 280% Overload for 20 seconds of Each 120 Seconds
    • 6.6 kv Rectifiers with Oversized DC Link Choke and Input Line Reactor
  • Modular Liquid Cooled Design:
    • Used in Multiple Motor Configurations, Add or Remove Motors as Required
    • Separate Controls in Skid or Wall Mounted Configuration
    • Closed Loop Liquid Cooling System Keeps VFD Cooler and Cleaner for Increased Life and Reliability
    • Motor Leads Up to 10 KM

4160 Volt VFD for Underground Belt Conveyor Controls

  • Modular Design Provides Flexibility in Number of Motors Used
  • Main or Booster Applications
  • Torque and Speed Control
  • Unlimited Conveyor Start Time Minimizes Belt Tensions:
    • Minimizes HP Required and Conveyor Component Sizes
    • Reduces TakeUp Requirements
    • Extends Belt Life
  • Allows Conveyor to Operate at Reduced Speeds:
    • When Less Than Design TPH is Required Conveyor Speed May Be Reduced
    • Belt Inspection Speed for Maintenance
  • Modular Liquid Cooled Design:
    • Used in Multiple Motor Configurations, Add or Remove Motors as Required
    • Separate Belt Controls in Skid or Wall Mounted Configuration
    • Closed Loop Liquid Cooling System Keeps VFD Cooler and Cleaner for Increased Life and Reliability
  • Lower Electrical Harmonics:
    • Active Front End Provides Regenerative Ability
    • Active Front End Meets IEEE-519 Requirements
    • SGCT Devices Use Slower Switching Frequencies Reducing Common Mode Noise
    • Eliminates Need for Drive Isolation Transformers
    • Eliminates Harmonics Damage to Electrical Distribution Equipment
    • Motor Lead Lengths Up to 10 KM
  • Reduces Installation Cost of Low Voltage:
    • Saves on Cable Cost
    • Smaller Cables Reduce Installation Time
    • For 400' of Cabling:
      • Saves Over $70,000 in Cable Cost
      • Requires Less Than 1/3 of Time to Install or Move

View/Download Medium Voltage VFD Powerpoint Presentation